The use of a new generation of uncooled infrared detectors, thermal sensitivity, the image more clearly. The use of more high-precision 14-bit digital image, can be found in more accurate temperature anomalies, can automatically capture full-screen high-temperature region, the realization of multi-regional high-temperature analysis, can set the upper limit alarm temperature is higher than the temperature alarm automatically. Equipment, compact structure, convenient installation, the internal integration of image acquisition, image processing and network communication modules, the reliability of design through the system with high efficiency and stability, the work can be completely divorced from the PC, multiple devices can be through a standard network connection, the composition of the regional monitoring alarm systems, fire detection can be achieved, the temperature anomaly alarm, such as non-contact temperature measurement function, is widely used in fire safety, security, power, petrochemical, metallurgical, medical and other fields.
Apply
? compact structure, small size, easy to install in production lines and various equipment for handling and movement;
? Equipment within the image acquisition, image processing and communication control module, such as highly integrated through the design of the system reliability with a high efficiency and stability, the work can be completely divorced from the PC;
? Use Intel Xscale PXA270 processor, with the x86 platform has some compatibility, device running Linux operating system, the original standard x86 platform C algorithm can be easily transplanted to the operation of the equipment;
? rich interface: multi-function 4 can be configured into four digital IO, VGA, Ethernet ports, serial and so on.
Performance parameters:
Vanadium oxide sensor (uncooled focal plane array Vanadium Oxide), the new generation of uncooled infrared focal plane detector type, image more clearly
7.5μm-13.5μm band work
Pixel size 38μmx38μm
Thermal Sensitivity <85mk @ f/1.6
Resolution of 320x240
9Hz framerate
Digital Output 8 and 14
Processor 32 Bit, Intel Xscale PXA270 processor, 520 MHz frequency
128 MB SDRAM memory
Size: 260 * 92 * 82cm
|

Cutting-edge technology: as the television cameras filming the same temperature distribution of the image. Resolution as high as 0.1 degrees Celsius. Richard H1N1 influenza, particularly high-performance high temperature. Even if the crowd moving in the Bop, but also a matter of seconds in a least one of the dozens of people from high-temperature (red, orange for the normal body temperature, the green for the high-temperature De).
Respect for human rights: those who do not have to stop being tested, or test stand.
Safety testing: testing can be far away from being tested or to sit in the glass away from the operating room
Automatic search, keep track
www.62965544.com
Rapid large-area temperature: 0.04 seconds detection time, real-time screening for high temperature, "the individual" sensitivity as high as 0.1 ℃
Automatically determine, automatic alarm: automatic search, abnormal body temperature immediately report to the police.
|

Main technique index
(1) Normal work condition
a. Environment temperature:15 ℃ ~ 35 ℃.
b. Opposite temperature:35%-85%.
c. Electricity source: DC3V (2 section AA battery).
(2) Basic size:Long* Breadth *High): 159 *89 *38 (mm);
(3) Weight: 220g;
(4) Distinguish rate: 0.1 ℃;
(5) Measuring scope: 35.0 ℃~ 42.0 ℃;
(6) Consuming power: ≦ 50 mW;
(7) Error margin: 0.2 ℃;
(8) Measuring time: 1 seconds ±0.3 seconds;
(9) Partition time each measuring:≦3 seconds;
(10) Measuring distance: ≦150 mm;
(11) Automatically shut down time:5s.
Setting
(1) Choice of the temperature unit
a. Keeping press the set key with time above 3 S , The LED show F-1;
b. This time to press "+" key to choose Celsius( ℃ )
c. Press the " — " key then to choose the Fahrenheit(.F).
(2) The caution value sets up
a.Keeping press the set key with time above 3s, The LED
|